  "cases": [
    {
      "id": "1",
      "inputs": {
        "annual_irradiance_kwh_m2": 1400,
        "area_ha": 4,
        "capacity_kw": 100,
        "coverage_pct": 35,
        "crop_yield_ratio": 0.7,
        "performance_ratio": 0.8,
        "reference_pv_yield_kwh_ha": 140000
      },
      "metrics": [
        {
          "label": "annual_energy_kwh",
          "unit": "",
          "value": 112000
        },
        {
          "label": "energy_per_ha_kwh",
          "unit": "",
          "value": 28000
        },
        {
          "label": "crop_relative_yield",
          "unit": "",
          "value": 0.7
        },
        {
          "label": "pv_relative_yield",
          "unit": "",
          "value": 0.2
        }
      ],
      "result": {
        "annual_energy_kwh": 112000,
        "assumptions": [
          "Annual energy (kWh) = rated capacity (kW) × annual plane-of-array irradiation (kWh/m²) ÷ reference irradiance (1 kW/m²) × performance ratio.",
          "Energy per hectare uses the full entered agrivoltaic field area; the reference PV yield must use a consistent land-area boundary and annual period.",
          "Land equivalent ratio = entered crop relative yield + annual agrivoltaic energy per hectare / entered reference PV energy per hectare.",
          "Coverage is recorded as metadata only. It does not secretly change energy or crop yield; no shading-response curve, crop model, tracking model or weather forecast is inferred.",
          "This is an explicit-input screening calculation, not measured production or a validated prediction. It does not include economics, storage dispatch or equipment actuation."
        ],
        "crop_relative_yield": 0.7,
        "energy_per_ha_kwh": 28000,
        "land_equivalent_ratio": 0.9,
        "pv_relative_yield": 0.2,
        "warnings": []
      },
      "rows": [
        {
          "indicator": "annual_energy_kwh",
          "value": 112000
        },
        {
          "indicator": "energy_per_ha_kwh",
          "value": 28000
        },
        {
          "indicator": "crop_relative_yield",
          "value": 0.7
        },
        {
          "indicator": "pv_relative_yield",
          "value": 0.2
        },
        {
          "indicator": "land_equivalent_ratio",
          "value": 0.9
        }
      ],
      "title": "100 kW · crop ratio 0.7"
    },
    {
      "id": "2",
      "inputs": {
        "annual_irradiance_kwh_m2": 1400,
        "area_ha": 4,
        "capacity_kw": 100,
        "coverage_pct": 35,
        "crop_yield_ratio": 1,
        "performance_ratio": 0.8,
        "reference_pv_yield_kwh_ha": 140000
      },
      "metrics": [
        {
          "label": "annual_energy_kwh",
          "unit": "",
          "value": 112000
        },
        {
          "label": "energy_per_ha_kwh",
          "unit": "",
          "value": 28000
        },
        {
          "label": "crop_relative_yield",
          "unit": "",
          "value": 1
        },
        {
          "label": "pv_relative_yield",
          "unit": "",
          "value": 0.2
        }
      ],
      "result": {
        "annual_energy_kwh": 112000,
        "assumptions": [
          "Annual energy (kWh) = rated capacity (kW) × annual plane-of-array irradiation (kWh/m²) ÷ reference irradiance (1 kW/m²) × performance ratio.",
          "Energy per hectare uses the full entered agrivoltaic field area; the reference PV yield must use a consistent land-area boundary and annual period.",
          "Land equivalent ratio = entered crop relative yield + annual agrivoltaic energy per hectare / entered reference PV energy per hectare.",
          "Coverage is recorded as metadata only. It does not secretly change energy or crop yield; no shading-response curve, crop model, tracking model or weather forecast is inferred.",
          "This is an explicit-input screening calculation, not measured production or a validated prediction. It does not include economics, storage dispatch or equipment actuation."
        ],
        "crop_relative_yield": 1,
        "energy_per_ha_kwh": 28000,
        "land_equivalent_ratio": 1.2,
        "pv_relative_yield": 0.2,
        "warnings": [
          "A land equivalent ratio above 1 follows from the entered assumptions; it is not evidence of a measured land-use benefit."
        ]
      },
      "rows": [
        {
          "indicator": "annual_energy_kwh",
          "value": 112000
        },
        {
          "indicator": "energy_per_ha_kwh",
          "value": 28000
        },
        {
          "indicator": "crop_relative_yield",
          "value": 1
        },
        {
          "indicator": "pv_relative_yield",
          "value": 0.2
        },
        {
          "indicator": "land_equivalent_ratio",
          "value": 1.2
        }
      ],
      "title": "100 kW · crop ratio 1"
    },
    {
      "id": "3",
      "inputs": {
        "annual_irradiance_kwh_m2": 1400,
        "area_ha": 4,
        "capacity_kw": 250,
        "coverage_pct": 35,
        "crop_yield_ratio": 0.7,
        "performance_ratio": 0.8,
        "reference_pv_yield_kwh_ha": 140000
      },
      "metrics": [
        {
          "label": "annual_energy_kwh",
          "unit": "",
          "value": 280000
        },
        {
          "label": "energy_per_ha_kwh",
          "unit": "",
          "value": 70000
        },
        {
          "label": "crop_relative_yield",
          "unit": "",
          "value": 0.7
        },
        {
          "label": "pv_relative_yield",
          "unit": "",
          "value": 0.5
        }
      ],
      "result": {
        "annual_energy_kwh": 280000,
        "assumptions": [
          "Annual energy (kWh) = rated capacity (kW) × annual plane-of-array irradiation (kWh/m²) ÷ reference irradiance (1 kW/m²) × performance ratio.",
          "Energy per hectare uses the full entered agrivoltaic field area; the reference PV yield must use a consistent land-area boundary and annual period.",
          "Land equivalent ratio = entered crop relative yield + annual agrivoltaic energy per hectare / entered reference PV energy per hectare.",
          "Coverage is recorded as metadata only. It does not secretly change energy or crop yield; no shading-response curve, crop model, tracking model or weather forecast is inferred.",
          "This is an explicit-input screening calculation, not measured production or a validated prediction. It does not include economics, storage dispatch or equipment actuation."
        ],
        "crop_relative_yield": 0.7,
        "energy_per_ha_kwh": 70000,
        "land_equivalent_ratio": 1.2,
        "pv_relative_yield": 0.5,
        "warnings": [
          "A land equivalent ratio above 1 follows from the entered assumptions; it is not evidence of a measured land-use benefit."
        ]
      },
      "rows": [
        {
          "indicator": "annual_energy_kwh",
          "value": 280000
        },
        {
          "indicator": "energy_per_ha_kwh",
          "value": 70000
        },
        {
          "indicator": "crop_relative_yield",
          "value": 0.7
        },
        {
          "indicator": "pv_relative_yield",
          "value": 0.5
        },
        {
          "indicator": "land_equivalent_ratio",
          "value": 1.2
        }
      ],
      "title": "250 kW · crop ratio 0.7"
    },
    {
      "id": "4",
      "inputs": {
        "annual_irradiance_kwh_m2": 1400,
        "area_ha": 4,
        "capacity_kw": 250,
        "coverage_pct": 35,
        "crop_yield_ratio": 1,
        "performance_ratio": 0.8,
        "reference_pv_yield_kwh_ha": 140000
      },
      "metrics": [
        {
          "label": "annual_energy_kwh",
          "unit": "",
          "value": 280000
        },
        {
          "label": "energy_per_ha_kwh",
          "unit": "",
          "value": 70000
        },
        {
          "label": "crop_relative_yield",
          "unit": "",
          "value": 1
        },
        {
          "label": "pv_relative_yield",
          "unit": "",
          "value": 0.5
        }
      ],
      "result": {
        "annual_energy_kwh": 280000,
        "assumptions": [
          "Annual energy (kWh) = rated capacity (kW) × annual plane-of-array irradiation (kWh/m²) ÷ reference irradiance (1 kW/m²) × performance ratio.",
          "Energy per hectare uses the full entered agrivoltaic field area; the reference PV yield must use a consistent land-area boundary and annual period.",
          "Land equivalent ratio = entered crop relative yield + annual agrivoltaic energy per hectare / entered reference PV energy per hectare.",
          "Coverage is recorded as metadata only. It does not secretly change energy or crop yield; no shading-response curve, crop model, tracking model or weather forecast is inferred.",
          "This is an explicit-input screening calculation, not measured production or a validated prediction. It does not include economics, storage dispatch or equipment actuation."
        ],
        "crop_relative_yield": 1,
        "energy_per_ha_kwh": 70000,
        "land_equivalent_ratio": 1.5,
        "pv_relative_yield": 0.5,
        "warnings": [
          "A land equivalent ratio above 1 follows from the entered assumptions; it is not evidence of a measured land-use benefit."
        ]
      },
      "rows": [
        {
          "indicator": "annual_energy_kwh",
          "value": 280000
        },
        {
          "indicator": "energy_per_ha_kwh",
          "value": 70000
        },
        {
          "indicator": "crop_relative_yield",
          "value": 1
        },
        {
          "indicator": "pv_relative_yield",
          "value": 0.5
        },
        {
          "indicator": "land_equivalent_ratio",
          "value": 1.5
        }
      ],
      "title": "250 kW · crop ratio 1"
    },
    {
      "id": "5",
      "inputs": {
        "annual_irradiance_kwh_m2": 1400,
        "area_ha": 4,
        "capacity_kw": 500,
        "coverage_pct": 35,
        "crop_yield_ratio": 0.7,
        "performance_ratio": 0.8,
        "reference_pv_yield_kwh_ha": 140000
      },
      "metrics": [
        {
          "label": "annual_energy_kwh",
          "unit": "",
          "value": 560000
        },
        {
          "label": "energy_per_ha_kwh",
          "unit": "",
          "value": 140000
        },
        {
          "label": "crop_relative_yield",
          "unit": "",
          "value": 0.7
        },
        {
          "label": "pv_relative_yield",
          "unit": "",
          "value": 1
        }
      ],
      "result": {
        "annual_energy_kwh": 560000,
        "assumptions": [
          "Annual energy (kWh) = rated capacity (kW) × annual plane-of-array irradiation (kWh/m²) ÷ reference irradiance (1 kW/m²) × performance ratio.",
          "Energy per hectare uses the full entered agrivoltaic field area; the reference PV yield must use a consistent land-area boundary and annual period.",
          "Land equivalent ratio = entered crop relative yield + annual agrivoltaic energy per hectare / entered reference PV energy per hectare.",
          "Coverage is recorded as metadata only. It does not secretly change energy or crop yield; no shading-response curve, crop model, tracking model or weather forecast is inferred.",
          "This is an explicit-input screening calculation, not measured production or a validated prediction. It does not include economics, storage dispatch or equipment actuation."
        ],
        "crop_relative_yield": 0.7,
        "energy_per_ha_kwh": 140000,
        "land_equivalent_ratio": 1.7,
        "pv_relative_yield": 1,
        "warnings": [
          "A land equivalent ratio above 1 follows from the entered assumptions; it is not evidence of a measured land-use benefit."
        ]
      },
      "rows": [
        {
          "indicator": "annual_energy_kwh",
          "value": 560000
        },
        {
          "indicator": "energy_per_ha_kwh",
          "value": 140000
        },
        {
          "indicator": "crop_relative_yield",
          "value": 0.7
        },
        {
          "indicator": "pv_relative_yield",
          "value": 1
        },
        {
          "indicator": "land_equivalent_ratio",
          "value": 1.7
        }
      ],
      "title": "500 kW · crop ratio 0.7"
    },
    {
      "id": "6",
      "inputs": {
        "annual_irradiance_kwh_m2": 1400,
        "area_ha": 4,
        "capacity_kw": 500,
        "coverage_pct": 35,
        "crop_yield_ratio": 1,
        "performance_ratio": 0.8,
        "reference_pv_yield_kwh_ha": 140000
      },
      "metrics": [
        {
          "label": "annual_energy_kwh",
          "unit": "",
          "value": 560000
        },
        {
          "label": "energy_per_ha_kwh",
          "unit": "",
          "value": 140000
        },
        {
          "label": "crop_relative_yield",
          "unit": "",
          "value": 1
        },
        {
          "label": "pv_relative_yield",
          "unit": "",
          "value": 1
        }
      ],
      "result": {
        "annual_energy_kwh": 560000,
        "assumptions": [
          "Annual energy (kWh) = rated capacity (kW) × annual plane-of-array irradiation (kWh/m²) ÷ reference irradiance (1 kW/m²) × performance ratio.",
          "Energy per hectare uses the full entered agrivoltaic field area; the reference PV yield must use a consistent land-area boundary and annual period.",
          "Land equivalent ratio = entered crop relative yield + annual agrivoltaic energy per hectare / entered reference PV energy per hectare.",
          "Coverage is recorded as metadata only. It does not secretly change energy or crop yield; no shading-response curve, crop model, tracking model or weather forecast is inferred.",
          "This is an explicit-input screening calculation, not measured production or a validated prediction. It does not include economics, storage dispatch or equipment actuation."
        ],
        "crop_relative_yield": 1,
        "energy_per_ha_kwh": 140000,
        "land_equivalent_ratio": 2,
        "pv_relative_yield": 1,
        "warnings": [
          "A land equivalent ratio above 1 follows from the entered assumptions; it is not evidence of a measured land-use benefit."
        ]
      },
      "rows": [
        {
          "indicator": "annual_energy_kwh",
          "value": 560000
        },
        {
          "indicator": "energy_per_ha_kwh",
          "value": 140000
        },
        {
          "indicator": "crop_relative_yield",
          "value": 1
        },
        {
          "indicator": "pv_relative_yield",
          "value": 1
        },
        {
          "indicator": "land_equivalent_ratio",
          "value": 2
        }
      ],
      "title": "500 kW · crop ratio 1"
    }
  ],
  "category": "energy",
  "description": "Inspect illustrative agrivoltaic energy and land-equivalent-ratio assumptions.",
  "edition": "Precomputed synthetic browser edition",
  "limits": "Scenario arithmetic is not measured crop response or evidence of a causal benefit.",
  "method": "Capacity × irradiation × performance ratio; crop and PV yield ratios summed.",
  "name": "Solstice Field Lab",
  "omitted_runtime_fields": [
    "elapsed_ms",
    "quoted_at",
    "calculated_at"
  ],
  "provenance": "Original synthetic fixtures generated from the project engine. No operational or personal records.",
  "slug": "solstice-field-lab",
  "source_visibility": "private",
  "subtitle": "Explore a shared-field scenario"
}