Solstice Field Lab
Explore a shared-field scenario
Inspect illustrative agrivoltaic energy and land-equivalent-ratio assumptions.
Explore the evidence
Select a precomputed synthetic case, inspect input assumptions and download its JSON evidence or result CSV.
Open Solstice Field Lab explorer →What this edition demonstrates
Capacity × irradiation × performance ratio; crop and PV yield ratios summed.
Scenario arithmetic is not measured crop response or evidence of a causal benefit.
The public website hosts a read-only synthetic projection. The full authenticated source application and its Git history are maintained privately.
All fixtures are fictional. No sign-in, customer records, operational writes or paid external model calls are involved.
Publication notices · Application metadataExplore the application directory
Governing Equations, Inputs, Outputs & Dimensional Conventions
Solstice Field Lab executes deterministic client-side calculations in the browser. Every scenario is governed by explicit mathematical formulations and unit checks:
Declared Units & Arithmetic Conventions: PV capacity in kW; annual irradiance in kWh/m²/yr; performance ratio (PR) dimensionless (0–1); field area in hectares (ha); energy yield in kWh/yr and kWh/ha/yr; Land Equivalent Ratio (LER) dimensionless.
Scope & Operational Boundary: Agrivoltaic energy and land-equivalent-ratio scenario calculations. Not developer tooling or measured agronomic/field-yield validation.
Launch Interactive Solstice Field Lab Runtime → · Read Full Methodology & Validation Notes → · Download JSON Dataset (run/catalog.json)
Verified Case Study & Held-Out Reference Table
Worked Verification Case: Case 1 (4 ha shared field, 100 kW agrivoltaic array, 35% coverage, irradiance = 1,400 kWh/m², PR = 0.80, crop yield ratio = 0.70, reference monoculture PV yield = 140,000 kWh/ha): Annual PV energy = 100 × 1,400 × 0.80 = 112,000 kWh (28,000 kWh/ha). PV relative yield = 28,000 / 140,000 = 0.20. Combined Land Equivalent Ratio (LER) = 0.70 + 0.20 = 0.90.
| Case ID | Area (ha) | PV Capacity (kW) | Irradiance (kWh/m²) | PR | Annual Energy (kWh) | Crop Ratio | PV Ratio | Combined LER |
|---|---|---|---|---|---|---|---|---|
| Case 1 (Low Density 100 kW) | 4.0 | 100 | 1,400 | 0.80 | 112,000 | 0.70 | 0.20 | 0.90 |
| Case 2 (Balanced 250 kW) | 4.0 | 250 | 1,400 | 0.80 | 280,000 | 0.68 | 0.50 | 1.18 |
| Case 3 (High Density 400 kW) | 4.0 | 400 | 1,400 | 0.80 | 448,000 | 0.55 | 0.80 | 1.35 |
How to Use Solstice Field Lab in 3 Reproducible Steps
- Select a Baseline Scenario or Practice Module: Open the interactive browser runtime and choose one of the shipped synthetic presets or diagnostic modules to load its verified input parameters and unit declarations.
- Inspect Intermediate Traces & Constraints: Review the computed ledger, error diagnostics (MAE/RMSE/margin/balance checks), or bilingual explanations alongside the governing equations documented on mkcore.co.technology/methodology/.
- Export Portable Evidence (JSON / CSV): Export your scenario results, assumptions, or local study plan as a self-contained JSON or CSV file for offline verification and local re-import.
Methodological & Boundary FAQs
What mathematical model and units does Solstice Field Lab use?
Solstice Field Lab applies E_annual (kWh) = Capacity (kW) × Irradiance (kWh/m²) × PR; Energy_per_ha = E_annual / Area (ha); PV_Yield_Ratio = Energy_per_ha / Ref_PV_Yield (kWh/ha); LER = Crop_Yield_Ratio + PV_Yield_Ratio. Units: PV capacity in kW; annual irradiance in kWh/m²/yr; performance ratio (PR) dimensionless (0–1); field area in hectares (ha); energy yield in kWh/yr and kWh/ha/yr; Land Equivalent Ratio (LER) dimensionless.
What are the operational boundaries and limitations of Solstice Field Lab?
Agrivoltaic energy and land-equivalent-ratio scenario calculations. Not developer tooling or measured agronomic/field-yield validation. All computations run deterministically in the browser on synthetic or precomputed demonstration fixtures.
How can I reproduce the benchmark results in Solstice Field Lab?
Open the interactive browser workspace at ./run/, select Case 1 to inspect the worked result (Case 1 (4 ha shared field, 100 kW agrivoltaic array, 35% coverage, irradiance = 1,400 kWh/m², PR = 0.80, crop yield ratio = 0.70, reference monoculture PV yield = 140,000 kWh/ha): Annual PV energy = 100 × 1,400 × 0.80 = 112,000 kWh (28,000 kWh/ha). PV relative yield = 28,000 / 140,000 = 0.20. Combined Land Equivalent Ratio (LER) = 0.70 + 0.20 = 0.90.), and export the JSON or CSV evidence ledger.
Engineering Attribution & Interconnected Research Hub
Authored and maintained by Mohammad Rezwan Khan, PhD (Aalborg University · BESS QA/QC & Power Systems Specialist). Canonical URL: https://mkcore.co.technology/agrivoltaics/ · Source revision: verified-rel · Runtime SHA-256 prefix: verified-sha256 · Repository provenance: https://github.com/mohammadrezwankhan/solstice-field-lab (private source engine; public deterministic browser projection).
Application Metadata (app.json) · AI / LLM Discovery Guide (llms.txt) · Full Technical Corpus (llms-full.txt) · Semantic Knowledge Graph (knowledge-graph.jsonld)
Explore the MKLab & ASTRA Research Ecosystem
- Mohammad Rezwan Khan, PhD — Core Authority & BESS QA/QC Hub
- Datacenter Twin Lab — 12-Lesson Power Systems & EMT Simulator
- HelioForge Energy Lab — Hybrid Solar-Wind-BESS Microgrid Dispatch
- ZephyrTrade — Wind-Market Quantitative Backtesting
- MKLab Directory — Complete 68-App Browser Engineering Suite
- HelioForge Energy Lab — Hybrid Microgrid Simulator
- Datacenter Twin Lab — Power Systems & BESS Ride-Through